The NexTract Pilot600 is a benchtop chromatography system that excels in both GMP and non-GMP environments. Its extensive flow and pressure capabilities make it versatile: it can produce technical batches, conduct scale-up studies, and manufacture small quantities of GMP-grade materials.
Technical features
l Available in both non-GMP and GMP versions to meet application requirements of different scenarios.
l Modular design for easy operation and maintenance; flexible configuration compatible with chromatography columns with an inner diameter of 25 mm to 200 mm.
l High-precision and large-flow plunger pump ensures stable flow rate and enables accurate gradient elution.
l Precision detector system supports on-line monitoring of variable-wavelength UV absorbance, conductivity, pH and other parameters.
l The ChromX software features an intuitive and user-friendly interactive interface with human-centered design. Fully automated control and method editing boost users’ efficiency in chromatographic operations.
l The software integrates system control, method editing, data analysis and report generation, as well as data recording and chromatogram analysis. It conducts real-time monitoring and recording of system operation chromatogram data to ensure data integrity, fully complying with FDA regulations.
Technical parameters
Model | NexTract Pilot600 | NexTract Pilot600G | |
GMP requirements | N/A | Yes | |
System pump | Type | Piston pump | Piston pump |
Flow rate | 0-600mL/min | 0-600mL/min | |
Pressure range | 0-2Mpa | 0-2Mpa | |
Mixer | Type | Magnetic stirring electric mixer | Magnetic stirring electric mixer |
Volume | Standard: 5mL Optional: 12mL | Standard: 5mL Optional: 12mL | |
UV detector | Wavelength range | V4- Variable four wavelength 200-800nm | V4- Variable four wavelength 200-800nm |
Conductivity detector | Detection range | 0.001- 999.999mS/ cm | 0.001- 999.999mS/ cm |
Detection accuracy | ±2% | ±2% | |
Number | 1, located in post- column, with temperature compensation | 1, located in post- column, with temperature compensation; Optional:Up to 2, located in pre-column and located in post- column | |
Temperature detector | Detection range | 0-100℃ | 0-100℃ |
Detection accuracy | ±1℃ | ±1℃ | |
pH detector | Detection range | 0-14 | 0-14 |
Detection accuracy | ±0.1 | ±0.1 | |
Bubble sensor | Number | 2, A pump and B pump each have one air sensor | 2, A pump and B pump each have one air sensor |
Valve | Automatic injection valve | Supports load, inject, waste, Max. working pressure: 3000psi | Supports load, inject, waste, Max. working pressure: 3000psi |
Inlet valve | Two 6-channel rotary valve, Peek | Two 4-channel diaphragm valve, Peek; Optional: Up to 4 inlet valves (14 inlets) | |
Column valve | Single-column valve, up to two valves can be connected. | Multi-channel,support each column bypass、down-load、up-load,IP (Intelligent Packing),Waste,two column series connection modes; PEEK,diaphragm valve,Integrated pre-column and post-column pressure sensors,20bar | |
Bubble trap valve | Online, bypass, waste | Online,bypass mode(20bar),PEEK,diaphragm valve | |
pH valve | / | Multi-channel,support bypass、online mode(20bar),Peek,diaphragm valve | |
Outlet valve | 6 channel | 4 channel, Peek, diaphragm valve; Optional: Up to 2 outlet valves (7 outlets) | |
Accessories | Workstation | Chrom X software | Chrom X software |
Installation toolkit | Includes PEEK/PTFE pipe, pipe connectors, column clamp, back pressure valve, installation manual, common tools | Includes PEEK/PTFE pipe, pipe connectors, column clamp, back pressure valve, installation manual, common tools | |