NexTract Pilot600 Chromatography system

The NexTract Pilot600 is a benchtop chromatography system that excels in both GMP and non-GMP environments. Its extensive flow and pressure capabilities make it versatile: it can produce technical batches, conduct scale-up studies, and manufacture small quantities of GMP-grade materials.

Technical features

l Available in both non-GMP and GMP versions to meet application requirements of different scenarios.

l Modular design for easy operation and maintenance; flexible configuration compatible with chromatography columns with an inner diameter of 25 mm to 200 mm.

l High-precision and large-flow plunger pump ensures stable flow rate and enables accurate gradient elution.

l Precision detector system supports on-line monitoring of variable-wavelength UV absorbance, conductivity, pH and other parameters.

l The ChromX software features an intuitive and user-friendly interactive interface with human-centered design. Fully automated control and method editing boost users’ efficiency in chromatographic operations.

l The software integrates system control, method editing, data analysis and report generation, as well as data recording and chromatogram analysis. It conducts real-time monitoring and recording of system operation chromatogram data to ensure data integrity, fully complying with FDA regulations.


  • Technical Details
  • URS
  • Download

Technical parameters

Model

NexTract Pilot600

NexTract Pilot600G

GMP requirements

N/A

Yes

System pump

Type

Piston pump

Piston pump

Flow rate

0-600mL/min

0-600mL/min

Pressure range

0-2Mpa

0-2Mpa

Mixer

Type

Magnetic stirring electric mixer

Magnetic stirring electric mixer

Volume

Standard: 5mL

Optional: 12mL

Standard: 5mL

Optional: 12mL

UV detector

Wavelength range

V4- Variable four wavelength 200-800nm

V4- Variable four wavelength 200-800nm

Conductivity detector

Detection range

0.001- 999.999mS/ cm

0.001- 999.999mS/ cm

Detection accuracy

±2%

±2%

Number

1, located in post- column, with temperature compensation

1, located in post- column, with temperature compensation;

Optional:Up to 2, located in pre-column and located in post- column

Temperature detector

Detection range

0-100

0-100

Detection accuracy

±1

±1

pH detector

Detection range

0-14

0-14

Detection accuracy

±0.1

±0.1

Bubble sensor

Number

2, A pump and B pump each have one air sensor

2, A pump and B pump each have one air sensor

Valve

Automatic injection valve

Supports load, inject, waste, Max. working pressure: 3000psi

Supports load, inject, waste, Max. working pressure: 3000psi

Inlet valve

Two 6-channel rotary valve, Peek

Two 4-channel diaphragm valve, Peek;

Optional: Up to 4 inlet valves (14 inlets)

Column valve

Single-column valve, up to two valves can be connected.

Multi-channel,support each column bypass、down-load、up-load,IP (Intelligent Packing),Waste,two column series connection modes;

PEEKdiaphragm valveIntegrated pre-column and post-column pressure sensors20bar

Bubble trap valve

Online, bypass, waste

Online,bypass mode(20bar),PEEK,diaphragm valve

pH valve

/

Multi-channelsupport bypassonline mode(20bar)Peekdiaphragm valve

Outlet valve

6 channel

4 channel, Peek, diaphragm valve;

Optional: Up to 2 outlet valves (7 outlets)

Accessories

Workstation

Chrom X software

Chrom X software

Installation toolkit

Includes PEEK/PTFE pipe, pipe connectors, column clamp, back pressure valve, installation manual, common tools

Includes PEEK/PTFE pipe, pipe connectors, column clamp, back pressure valve, installation manual, common tools


Brochure

User’s Manual

    NexTract Pilot600 Chromatography system
Thank you for your interest!

Please enter your e-mail address and we will send you the User’s Manual ASAP

Online Message

If you have any needs, please fill out the form below and we will contact you as soon as possible.