NexTract Chromatography system

NexTract Chromatography System is a full-featured, flexibly configurable and compactly designed chromatography system for laboratory-level research and method development, capable of efficiently performing separation and purification of complex biological samples ranging from micrograms to tens of grams. The system supports a variety of chromatography techniques and meets the automation requirements required to provide high purity. The system can be freely configured and upgraded at any time, and offers a variety of options based on your purification needs to further improve its performance.

  • Modular design, flexible expansion.

  • High-precision plunger pump with titanium alloy pump head, better biocompatibility and corrosion resistance.

  • Integrated valve design, minimizes the overall delay volume in the flow path, improve the separation efficiency.

  • pH valve enabling multiple flow path schemes without the need of disassembling during calibrations

  • Software integrated DOE functionality, allowing for minimal experimental input and intelligent analysis to achieve optimal process conditions and results.

  • Practical size for easy placement on a laboratory bench or in a freezer.


  • Technical Details
  • URS
  • Download

 Model

NexTract025

NexTract150

System pump

Type

Piston pump, titanium alloy pump head

Flow rate

0.001-25mL/min

0.01-150mL/min

Flow rate accuracy

±1.2%

±1.2%

Flow rate precision

RSD<0.5%

RSD<0.5%

Pressure range

0-34Mpa

0-10Mpa

MIxer

Type

Magnetic stirring electric mixer

Volume

Standard: 1.4mL

Optional: 0.6mL

Standard: 2mL

Optional: 5mL

UV detector

Wavelength range

(Choose one of three)

F2-Fixed dual wavelength 254+280nm

V2-Variable dual wavelength detector, 190-400nm

V4-Variable four wavelength DAD detector, 200-800nm

Conductivity detector

Detection range

0.001- 999.999mS/ cm

Detection accuracy

±2%

Temperature detector

Detection range

0-100℃

Detection accuracy

±1℃

pH detector

Detection range

0-14

Detection accuracy

±0.1

Valve

Automatic injection valve

Supports load, inject, waste, Max. working pressure: 3000psi

Inlet valve

8 channel inlet valve with built-in bubble sensor/2 channel inlet valve

Column valve

Single column valve, can be connected to 1 column, support forward and reverse flushing, bypass function, withstand pressure: 20Mpa

Five column valve, can be connected to 5 column, support forward and reverse flushing, bypass function, withstand pressure: 20Mpa

Outlet valve

2/12 channel

pH valve

Five modes, supports pH and flow restrictor online simultaneously, pH online, flow restrictor online, bypass, calibration

Bubble sensor

External bubble sensor, real-time detection of air bubbles in the pipeline

Column pressure detector

Monitor pre and post column pressure

Sample pump (Includes an 8 channel sample selection valve with an integrated bubble sensor)

Flow rate

0.001-25mL/min

0.01-150mL/min

Pressure range

0-34Mpa

0-10Mpa

Accessories

Workstation

Chrom X software

Installation toolkit

Includes PEEK/PTFE pipe, pipe connectors, column clamp, back pressure valve, installation manual, common tools

Fraction collector

Open type

Supports automatic identification of double trays, support 96, 48, 24 deep hole plate, 1.5mL, 15, 50mL centrifugal tube tray collection

Fully enclosed temperature control collector

Refrigeration range: 6-20 ℃, support 96, 48, 24 deep hole plate, 1.5mL, 15, 50mL centrifugal tube tray collection