YC-SPS Chromatography system

The YC-SPS protein chromatography system is a small, compact chromatography system designed for laboratory-scale protein purification, desalting and small-scale preparation. With a single pump drive, the system is compact, easy to operate, and has excellent stability and reproducibility to meet the diverse needs of researchers in the purification of biomolecules.

  • Compact structure with a simple and flexible configuration, easy to operate and use.

  • High-precision plunger pump with titanium alloy pump heads ensure stable and reproducible flow rates, as well as better biocompatibility and corrosion resistance.

  • Adaptable to a wide range of columns and packings, supporting manual or automatic fraction collection, and easy to combine with detectors (e.g., UV, pH, conductivity monitoring).

  • Single pump system with inlet 3-way valve for buffer selection and gradient formation.

  • The single pump system reduces cost and maintenance while maintaining performance, making it ideal for primary screening and routine purification.


  • Technical Details
  • URS
  • Download

 Model

YC-SPS025

YC-SPS150

System pump

Type

Piston pump, titanium alloy pump head

Flow rate

0.001-25mL/min

0.01-150mL/min

Flow rate accuracy

±1.2%

±1.2%

Flow rate precision

RSD<0.5%

RSD<0.5%

Pressure range

0-34Mpa

0-10Mpa

Mixer

Type

Magnetic stirring electric mixer

Volume

Standard: 1.4mL

Optional: 0.6mL

Standard: 2mL

Optional: 5mL

UV detector

Wavelength range

(Choose one of two)

F2-Fixed dual wavelength 254+280nm

V2-Variable dual wavelength detector, 190-400nm

Conductivity detector

Detection range

0.001- 999.999mS/ cm

Detection accuracy

±2%

Temperature detector

Detection range

0-100℃

Detection accuracy

±1℃

Valve

Automatic injection valve

Supports load, inject, waste, Max. working pressure: 3000psi

Inlet valve

2 channel inlet valve

Outlet valve

2 channel outlet valve

Accessories

Workstation

Chrom X software

Installation toolkit

Includes PEEK/PTFE pipe, pipe connectors, column clamp, back pressure valve, installation manual, common tools

Optional configuration

Bubble sensor

External bubble sensor, real-time detection of air bubbles in the pipeline

pH detector

Detection range: 0-14

Column valve

Five column valve, can be connected to 5 column, supports

forward and reverse flushing, bypass function, withstand

pressure:3000 psi

 

Column pressure sensor

Monitor pre and post column pressure

Fraction collector

Supports automatic identification of double trays, support 96, 48, 24 deep hole plate, 1.5mL, 15, 50mL centrifugal tube tray collection


Brochure

User’s Manual

    YC-SPS Chromatography system
Thank you for your interest!

Please enter your e-mail address and we will send you the User’s Manual ASAP

Online Message

If you have any needs, please fill out the form below and we will contact you as soon as possible.